• Surface tops manufactured in 2 mm thick AISI- 304 stainless steel.
• Laser-cut joints, automatic welding and polishes. Screws hidden from view.
• Double walled lid balanced by means of a hinge with front handle, with diagonal opening to 75° which allows the lid to be kept open in any position.
• Tank inbuilt into the surface top by robotic welding, manufactured in AISI-304 stainless steel, with the bottom of the tank in AISI-316L stainless steel.
• Tank filling with hot or cold water by electrovalve, activated with a single switch located on the front panel.
• Tank emptying by 2” safety valve with handle in athermic material and safe and effortless handling.
• Robust and reliable filter for draining the tank manufactured in AISI-304 stainless steel. Easily extractable.
• Controls with protective base and system against water infiltration.
• High temperature enamelled cast iron flue protector.
• Access to the components from the front.
• Machines with IPX5 grade water protection.

Bain marie electric models

• Heating by heating elements located in the lower part of the bain marie.
• Heating controlled by energy regulator and pressure switch.
• Bain marie chamber around the tank, with automatic filling system when the machine is connected.
• Automatic chamber level control with quadruple security: pressure switch to control the pressure in the chamber, overpressure security valve, thermostat to limit overheating in the chamber and pressure gauge incorporated into the surface top.
• Automatic flushing of the chamber.
• Heating at the bottom of the pan acts on the water in the surrounding chamber, meaning that the saturated steam generated at a temperature of 107 °C heats the bottom and sides of the tank in a uniform manner. The temperature reached is lower than that obtained with direct heating.
• Inbuilt pan floor to avoid deformations.
• Indicator light to show when the machine is connected and when it is heating.

  Model No of Tank Tank capacity in l Power kW Dimensions (mm) Data sheet
M-E910 BM M-E910 BM 600x400 100 22,00 800x930x850 Download
M-E915 BM M-E915 BM 600x550 150 22,00 800x930x850 Download

Bain marie gas models

• Bain marie chamber around the tank, with automatic filling system when the machine is connected.
• Automatic chamber level control with quadruple security: pressure switch to control the pressure in the chamber, overpressure security valve, thermostat to limit overheating in the chamber and pressure gauge incorporated into the surface top.
• Automatic flushing of the chamber.
• Heating at the bottom of the pan acts on the water in the surrounding chamber, meaning that the saturated steam generated at a temperature of 107 °C heats the bottom and sides of the tank in a uniform manner. The temperature reached is lower than that obtained with direct heating.
• Inbuilt pan floor to avoid deformations.
• Indicator light to show when the machine is connected and when it is heating.

  Model No of Tank Tank capacity in l Power kW Dimensions (mm) Data sheet
M-G910 BM M-G910 BM 600x400 100 20,00 800x930x850 Download
M-G915 BM M-G915 BM 600x550 150 24,00 800x930x850 Download

Direct fire gas models

GAS MODELS
• Group of optimised combustion stainless steel tubular burners, controlled by energy regulator and by pressure switch
• Control by energy regulator and by pressure switch, permitting lower water and energy consumption.
• Ignition of group of burners by spark train. There is also an access tube for manual ignition.


• Group of sequentially operating, optimized combustion stainless steel tubular burners, controlled by energy regulator.
• Heating from the burners at the bottom of the pan covers the base in a uniform manner, to give progressive heating of the contents of the tank.
• Option of regulating the heating by the burners, with different degrees of power.
• Ignition of group of burners by spark train.There is also an access tube for manual ignition.
• Indicator light to show when the machine is connected and when it is heating.

  Model No of Tank Tank capacity in l Power kW Dimensions (mm) Data sheet
M-G910 M-G910 600x400 100 20,00 800x930x850 Download
M-G915 M-G915 600x550 150 24,00 800x930x850 Download
M-G920 M-G920 600x650 200 24,00 800x930x850 Download

Pressure gas models

• Group of sequentially operating, optimized combustion stainless steel tubular burners, controlled by energy regulator.
• Heating from the burners at the bottom of the pan covers the base in a uniform manner, to give progressive heating of the contents of the tank.
• Option of regulating the heating by the burners, with different degrees of power.
• Ignition of group of burners by spark train.There is also an access tube for manual ignition.
• Indicator light to show when the machine is connected and when it is heating.

  Model No of Tank Tank capacity in l Power kW Dimensions (mm) Data sheet
MP-G910 MP-G910 600x400 100 20,00 800x930x850 Download
MP-G915 MP-G915 600x550 150 24,00 800x930x850 Download
MP-G920 MP-G920 600x650 200 24,00 800x930x850 Download
Would you like more information? Contact us!
  • The Name and Surname field is obligatory.
  • The E-mail field is obligatory. Enter a valid e-mail address.
  • The telephone field is obligatory. The format of the number is incorrect. Please enter number again.
  • The Country field is obligatory.
  • The Query field is obligatory.
You must confirm acceptance of the privacy policy.
* Obligatory fields

The information has been sent. Thank you for contacting us. We shall study your request and reply as soon as possible.

Back

An error has occurred. Please try again.