BLAST CHILLERS AND FREEZERS - CONCEPT +

Back

Compact blast chillers Concept +

Our ATM blast chillers offer different sizes to suit every user’s needs. All of them, from the small table top blast chillers to the large size freezers with capacity for GN2/1 trays, are fitted with an electronic control system entirely developed by Fagor Industrial R & D & i.

  Model Capacity GN Voltage (V) Electric/Cooling power (W) Dimensions (mm) Data sheet
EATM-031 EATM-031 3 GN-1/1 230V-1N 410/565 590x700x520 Download
ATM-031 CD ATM-031 CD 3 GN-1/1 230V-1N 590/490 560x700x514 Download
ATM-051 CD ATM-051 CD 5 GN-1/1 230V-1N 1200/690 790x700x850 -
ATM-081 CD ATM-081 CD 8 GN-1/1 230V-1N 2000/1300 790x800x1.290 Download
ATM-101 CD ATM-101 CD 10 GN-1/1 230V-1N 2000/1300 790x800x1.420 Download
ATM-121 CD ATM-121 CD 12 GN-1/1 230V-1N 2000/1300 790x800x1.600 Download
ATM-161 CD ATM-161 CD 16 GN-1/1 400V-3N 3500/2850 790x800x1.950 Download
ATM-102 CD ATM-102 CD 20 GN-1/1 400V-3N 2300/2850 1.200x1.090x1.766 Download

ATM series

• Mixed models, for chiller blasting (+3 ºC) or freezing cycles (-18 ºC).
• There two working options both for chiller blasting and freezing:
- Power cycle: for over 2 cm thick compact products. 
- Soft cycle: for less than 2 cm thick or low density products. The cycle is run in two programmed stages. The soft cycle prevents frost on the product.
• Cycle duration:
- Refrigerating cycle: 90 minutes.
- Freezing cycle: 240 minutes.
• Electronic timer and temperature sensor.
• The cycles can be controlled by time or by temperature according to the reading of the temperature sensor inside the product (time control is automatically applied when no probe is used).
• When the refrigerating cycle is over, the equipment works as a refrigerated cabinet, and the temperature remains between +2 and +4 ºC, or as a freezer, with temperatures under -18 ºC.
• Hermetically sealed compressor with ventilated condenser.
• R-404A ecological cooling (CFC free).
• 60 mm injected polyurethane isolation (except for the ATM-031 model, with 35 mm thick isolation). 40 kg/m3 density. CFC free.
• Copper piping and aluminium flaps evaporator.
• Forced draught cooling system.
• Automatic evaporation of defrosting water.
• Inner tray slides included.

Ordering options:
• Heated probe.
• HACCP printer.

ATM series

• Mixed models, for chiller blasting (+3 ºC) or freezing cycles (-18 ºC).
• There two working options both for chiller blasting and freezing:
- Power cycle: for over 2 cm thick compact products.
- Soft cycle: for less than 2 cm thick or low density products. The cycle is run in two programmed stages. The soft cycle prevents frost on the product.
• Cycle duration:
- Refrigerating cycle: 90 minutes.
- Freezing cycle: 240 minutes.
• Electronic timer and temperature sensor.
• The cycles can be controlled by time or by temperature according to the reading of the temperature sensor inside the product (time control is automatically applied when no probe is used).
• When the refrigerating cycle is over, the equipment works as a refrigerated cabinet, and the temperature remains between +2 and +4 ºC, or as a freezer, with temperatures under -18 ºC.
• Hermetically sealed compressor with ventilated condenser.
• R-404A ecological cooling (CFC free).
• 60 mm injected polyurethane isolation (except for the ATM-031 model, with 35 mm thick isolation). 40 kg/m3 density. CFC free.
• Copper piping and aluminium flaps evaporator.
• Forced draught cooling system.
• Automatic evaporation of defrosting water.
• Inner tray slides included.

Ordering options:
• Heated probe.
• HACCP printer.

Would you like more information? Contact us!
  • The Name and Surname field is obligatory.
  • The E-mail field is obligatory. Enter a valid e-mail address.
  • The telephone field is obligatory. The format of the number is incorrect. Please enter number again.
  • The Country field is obligatory.
  • The Query field is obligatory.
You must confirm acceptance of the privacy policy.
* Obligatory fields

The information has been sent. Thank you for contacting us. We shall study your request and reply as soon as possible.

Back

An error has occurred. Please try again.